Alltrax controller fault codes

I have an Alltrax SPM 72400 and was having troubles with it. All I get is a single blinking green LED light. The single blink indicates a 0-5k throttle. I tried to clear and reset the throttle but the controller LED light never goes to a solid "ready" green. Also I get no throttle response when the throttle type is set to USB or absolute.

Alltrax over current and shutdown 04 DS Last year I purchased a package from D&D motors that included a motor, wiring kit, HD solenoid and an Alltrax controller D&D 500 REGEN CC I0 5022 - TS which is a XCT48500-IQ.XCT Blink Codes. On power up, the controller will blink out a throttle code and then a Status or Error Code (see below) Throttle codes: 1 Green LED Flash = 0-5k throttle 2 Green LED Flash = 5K-0 throttle 3 Green LED Flash = 0-5V throttle 4 Green LED Flash = EZGO ITS throttle 5 Green LED Flash = Club Car, G19, G22Alltrax XCT controller Short Circuit/Output Fault Electric EZGO Home: FAQ: Donate: Who's Online : Buggies Gone Wild Golf Cart Forum ... Online : Buggies Gone Wild Golf Cart Forum > Golf Cart Repair and Troubleshooting > Electric EZGO: Cart won't go. Alltrax XCT controller Short Circuit/Output Fault User Name: Remember Me? Password: Register ...

Did you know?

Yesterday, I installed a new Alltrax SPM 48500 controller, heavy duty solenoid, heavy duty f/r switch, D&D 170-010-0002 speed and torque motor, and heavy duty cables. I powered the cart up after installing everything and the cart didn't move an inch. I looked at the controller and noticed the Led indicator light was blinking 2 green lights ...Alltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send requests and comments to: [email protected]Alltrax stepped up and designed a NEW product with a NEW warranty, the NCX Non-Programmable controllers. A cost effective solution to replace your aging or damaged stock controller without buying a "rebuilt controller". Programmable via RS232 comm port using PC or Laptop. Integrated anodized heat-sink with multi bolt pattern for flexibility.However when we turn it on the LED status light on the Alltrax SPM 72300 motor controller starts out with the solid green which indicates that it is ready to run. When we pull the throttle it switches to one green six red which indicates a "pre charge failure." ... It might throw a fault if the resistance is too low, or if the resistor itself ...

Voltage: * 36 Volt 48 Volt. Optional Solenoid: * None 400 Amp Main Solenoid w/ Diode & Resistor - $122. Add to Wish List. SKU: CON-SR48600-EZGo. Availability: In Stock. Product Description. Alltrax SR-48600 Motor Controller.from Alltrax and it is not necessary to re-program unless the customer has specific needs. If the controller does need to be programmed it can be done via a USB A to B cable and the Alltrax Toolkit program. Visit our website for more information on programming the controller including the Alltrax Toolkit Manual (DOC113-002) and instructional ...Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV.XCT485001264/1268 36 or 48 Volt 500 Amp. $ 1,038.00 – $ 1,069.00. Curtis 1266 Replacement. Please call Alltrax technical support about your application for this controller at 541-476-3565. Select options.

pairs, improper installation, submersion, alterations or use contrary to. any instructions provided by Alltrax in verbal or written form. In the event you should need warranty repair, contact Alltrax at (541) 476-3565 to receive warranty service authorization instructions for. returning the defective product to Alltrax for evaluation.any instructions provided by Alltrax in verbal or written form. In the event you should need warranty repair, contact Alltrax at (541) 476-3565 to receive warranty service authorization instructions for returning the defective product to Alltrax for evaluation. Products or parts shipped by customer to Alltrax must be sent postage paid andAlltrax SR48400 Series Motor Controller EZGo TXT & Marathon Golf Carts. $533.00. 1 review Write a Review. Throttle Type: * 0-5K 2-Wire (EZGo Marathon '94 & Older) ITS (EZGo '95 & Newer) w/ FREE Mount BRKT. Voltage: * 36 Volt 48 Volt.…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Alltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send re. Possible cause: 1/15/2007 12:36:00 PM Doc120-017-B_OP-Controller-Pro ...

Swap the F1 and F2 wires at the controller to correct the operation direction. I don't suppose you could tell us if the controller is flashing a red fault code when you try to go? Or better, connect a laptop and see if the throttle progress bar in the monitor screen is showing 0-100% when the pedal is depressed ( key on / in neutral)Key Features: Thermal plastic enclosure ABS. 36 or 48 volt models. 300, 400 or 500 amp models. Standard connectors for Club Car, EZGo, Yamaha G19/G22 and YDRE. Flexible USB programming. Integrated heatsink mounts on any suitable surface. Solenoid Control Output for "Main DC Contactor Control". Universal-Mount for no drill install included ...

Alltrax DCX400 Troubleshoot ??? I have an Alltrax DCX400PDS controller whereby the LED Green light does not turn off when the key is switched off. I have verified that the wiring is correct, etc. WIth the KS off and the Run/Maintenance switch in run the light gives 4 green flashes (ITS input) and then goes to a steady green with the key off or on.To fix the LED light blinking 7 times-. Firstly, check the voltage between Control B+ and B-. If the voltage on the battery is +/-5V higher than the pack voltage, check the wires connected to the solenoid. In care any of the wires connecting to the solenoid are damaged or broken, replace or fix the wires accordingly.Programming Cable for the Alltrax AXE and DCX Controllers USB-RS232. $23.00. No reviews yet Write a Review. On Back Order. Add to Wish List. SKU: ACC-USB-RS232. Availability: Out of Stock.

walmart dc 7086 Type: Series Motor Controller Operating Frequency: 18kHz Controller Voltage, KSI & Reverse: SR48XXX 12-48V nom, 62V max SR72XXX 12-72V nom, 90V max Controller Operating Temp:-20°C to 75°C, shutdown @ 85°C ... ALLTRAX www.alltraxinc.com . Created Date: 10/24/2017 10:59:22 AM ... 8182247little athens ambridge Page 1 Solid Red: Controller in programming mode may be rejected. Mini-Manual Alltrax reserves the right to repair or replace merchandise at its option at Solid Yellow: Controller throttle is wide no cost to the customer, except for shipping costs of sending the defect open, controller is supplying max output, For Stock PDS &...Location: West Virginia. Posts: 19,654. Re: Cart won't go. Alltrax XCT controller Short Circuit/Output Fault. Disconnect them from the controller and measure the Ohms between the wires/cables going to the motor. The field map loaded indicates you have an Admiral MOT-B2 or something similar and I don't have any specs on what the Ohmic reading ... sobr stocktwits Feb 11, 2014 · From there, page 28: "1 Green and 6 Red LED Flash = Pre-charge Failure". Since it seems that precharge for this controller means "Keep the circuit always powered" it could either be your resistor being burned off or the caps in the controller blew. Easiest is probably to contact Alltrax and ask them for advice.I have taken it completely apart and removed all wiring motor and controller. All parts that moved I replaced. I'm new to golf carts but thought I could do it based on most of the wiring being plug and play. I decided to upgrade the controller to a Alltrax 400amp XT controller, 400 amp heavy duty contactor and a new Admiral A2 10hp motor. food stamp office gulfport msbroad city star glazer crossword cluecoupons for grubhub that work Looked at controller (sr48500) and it's giving the blink code for pre-charge failure. Unsure what to check. Everything is new (less than a month) and has been working great. the maze unblocked 1996 txt series alltrax npx 2 red lights fault code Electric EZGO. Home: FAQ: Donate: Who's Online : Buggies Gone Wild Golf Cart Forum > Golf Cart Repair and Troubleshooting > Electric EZGO: 1996 txt series alltrax npx 2 red lights fault code User Name: Remember Me? Password: Register: Golf Cart Pics: Site Sponsors ... how to bypass lightspeed filter agentm 522 white pillgarage sales in mitchell sd Fault is displayed when both zero crosses are missing from the controller's input for 1.5 seconds or more. Could be a faulty excitation winding, zero cross circuit, loose wiring, or fieldRemove the M- wire from terminal J9 on the Alltrax XCT48400-PDS, flip the Run/Tow switch to Run, turn the key on and check the blink codes. If the one green/one red isn't displayed, the problem isn't the controller. If it does still report the one green/one red error, the problem is in the controller.