Common array manager software

 Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. .

Sun StorageTek Array Administration Guide For Sun StorageTek Common Array Manager, Release 6.2: PDF: Sun StorageTek Common Array Manager CLI Guide, Release 6.2.0: HTML: PDF: Sun StorageTek Common Array Manager CLI Guide for the J4000 Array Family: HTML: PDF: Sun StorageTek Common Array Manager User … Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options are also provided. The Sun StorageTek Common Array Manager software is a web-based management software that provides both a browser interface and a command-line interface (CLI) for configuring and managing arrays on an external management host. Management host platforms can be: Note - Windows XP Home Edition is not supported.

Did you know?

The array management software saves the configuration to allow access control between the specified SAS ports and targets. 7. Click Export to save the configuration to a template (see the Online Help for more information about creating SAS Access Configuration templates. ... Sun Storage Common Array Manager saves the current SAS domain ... The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.0: Enhancements to Auto Service Request (ASR) functionality. Support for Sun StorageTek FLX240, FLX280, and FLX380 Arrays. Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.

How to Download Common Array Manager (CAM) Software and Patches [ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.With new arrays, the mapping of the access LUN to the default domain is installed at the factory. If you lose this mapping, before installing in-band, use out-of-band management and the Common Array Manager software to re-map the access LUN to the default domain. See the Online Help in the software for more information about mapping. The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. As part of the installation of the Common Array Manager software, the script puts the array firmware files in a directory on the management host. When you upgrade the firmware, the software analyzes the firmware installed on the array. If the firmware on the host is newer, and you choose to install, the software installs the firmware on the array.The Sun Storage Common Array Manager Installation and Setup Guide describes how to install Oracle’s Sun Storage Common Array Manager software and how to perform initial configuration for RAID and JBOD open systems storage arrays. For help with installing the arrays, see the hardware installation guide for your array.

Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version …Download popular programs, drivers and latest updates easily No specific info about version 6.9. Please visit the main page of Sun Storage Common Array Manager CLI on Software Informer. ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Common array manager software. Possible cause: Not clear common array manager software.

Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training for documentation links. As part of the installation of the Common Array Manager software, the script puts the array firmware files in a directory on the management host. When you upgrade the firmware, the software analyzes the firmware installed on the array. If the firmware on the host is newer, and you choose to install, the software installs the firmware on the array.

The Sun StorageTek Common Field Manager User Guides for of J4000 Array Family is a combined software installation the user guide. This guiding describes like to install management and configuration soft. Sun StorageTek Common Array Corporate User Guide since the J4000 Alignment Family: HUNDRED H A P T E R ... 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet n.n.n.n. 3. After logging in, switch user to root: $ su -

secret double octopus To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: ... User names in the array management software must be currently defined users on the host. To add new users to hosts running Solaris …See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS. flights from nyc to barcelonafrom los angeles to las vegas flight Bug fixes that correct previous known software problems. Controller and Disk Firmware Updates. Controller and disk firmware has been updated with this release. See the Sun Storage Common Array Manager Baseline Firmware Reference, Version 6.10 for more information. Service Advisor ASR Update www.usbankrewardscard.com 2. Instructions to download Common Array Manager (CAM). Method 1 - Searching with the MOS patch number: Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download.Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. part time ufonewark to delhi indiapoe.ckm 2 Sun Storage Common Array Manager Software 6.8.1 Release Notes • September 2011 About the Software Sun Storage Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor storage arrays. The software includes a distributed architecture enabling you to designate local and Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest. digiskills List the management software application that<br /> you are logged in to.<br /> Modify the management software application<br /> that you are logged into.<br /> Show all of the operating systems that are<br /> supported by the array. The values returned can<br /> be used in subsequent requests to create or<br />Software: Common Array Manager, version 6.8.1. License Term: Perpetual (subject to termination under the SLA) Licensed Unit: Software Copy. Licensed unit Count: Unlimited. Permitted Uses: You may reproduce and use the Software for Your own Individual, Commercial, or Research and Instructional Use, subject to and conditioned on. flexmlimage in cameradoyoulike Sun Storage 2540 Array - Version Not Applicable and later Sun Storage Flexline 380 Array - Version Not Applicable and later All Platforms Goal. Automatic Service Request (ASR) is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur.